FREQUENTLY ASKED QUESTIONS
Voltnex Power provides installation guidance for a wide range of industrial power equipment, including isolation transformers, dry type transformers, industrial transformers, automatic voltage regulators (AVR), variable frequency drives (VFD), static var generators (SVG) and active harmonic filters (AHF). Guidance can cover equipment positioning, electrical connections, grounding, ventilation, protection, parameter configuration, testing and commissioning.
Before installation, the equipment’s rated power, input voltage, output voltage, frequency, phase configuration, load type and installation environment should be confirmed. Voltnex Power supplies customized industrial transformers from approximately 1kVA to 3000kVA, with voltage configurations from 100V to 690V, depending on project requirements. The correct wiring diagram, terminal arrangement and protection requirements should also be reviewed before energization.
A dry type transformer should be installed on a stable and suitable foundation with adequate clearance around the equipment for ventilation, heat dissipation, inspection and maintenance. The primary and secondary connections must match the specified voltage and phase configuration, while the transformer enclosure and core should be properly grounded. Before energization, cable connections, terminal tightness, insulation condition, phase sequence and protection devices should be checked.
Yes. Proper grounding is an important part of industrial transformer installation. The transformer enclosure and other required grounding points should be connected according to the equipment design and applicable electrical standards. Correct grounding helps improve electrical safety and provides an appropriate path for fault currents. Grounding connections should be inspected for secure terminals and suitable conductor sizing before commissioning.
Adequate ventilation is required to dissipate heat generated during normal operation. The required clearance depends on the equipment power rating, enclosure design, cooling method and installation environment. Dry type transformers, AVRs, VFD cabinets, SVG systems and AHF systems should not have their cooling openings blocked. High-power installations may require additional ventilation or cooling provisions based on the actual operating conditions.
Yes. Voltnex Power provides installation and commissioning guidance for VFD systems from 0.75kW to 1000kW, depending on the application. Guidance can include AC input wiring, motor output wiring, grounding, control terminals, shielded cables, input protection, cooling, motor rated-current settings, acceleration and deceleration parameters, frequency settings, overload protection, PID functions and communication interfaces such as Modbus RTU.
AVR installation normally involves verifying the input and output voltage, phase configuration, rated capacity, power connections, grounding, bypass circuit and protection devices. Before startup, the input voltage and wiring should be checked against the AVR specifications. During commissioning, the output voltage, load current, regulation performance, alarm functions and protection settings should be verified under controlled operating conditions.
A pre-energization inspection should verify the mechanical installation, input and output wiring, terminal tightness, grounding, phase sequence, voltage configuration, cable connections, circuit protection, ventilation and control wiring. Depending on the equipment, insulation resistance, no-load voltage, cooling fans, alarms and control functions may also need to be checked before the equipment is energized.
Yes. Voltnex Power can provide remote technical installation and commissioning support for suitable projects. Support may include wiring verification, parameter configuration, startup procedures, alarm identification, troubleshooting and performance verification. For qualified industrial projects, on-site commissioning support can also be coordinated depending on the project location, equipment type and service requirements.