About BK Series

The BK Series industrial control transformer is designed to provide stable and reliable control power for electrical machinery, automation equipment, machine tools, CNC systems and industrial control cabinets.

It converts the available primary power supply into the required control voltage for contactors, relays, solenoid valves, PLC circuits, indicators and other control components.

Voltnex Power offers standard and customized BK Series control transformers with different power ratings, voltage combinations, winding materials, insulation classes and mounting configurations to meet your specific industrial requirements.

Available in capacities from 25VA to 100kVA with customizable voltage options and Class B/F insulation to meet industrial standards.

Wide Range of Applications

CNC Machines

CNC Machines
Stable control power for CNC circuits & equipment.

Machine Tools

Machine Tools
Suitable for lathes, milling & grinding machines.

Control Cabinets

Control Cabinets
Powers contactors, relays and switches.

Factory Automation

Factory Automation
Used in automated production lines.

Motor Control

Motor Control
Supports circuits for motors & starters.

Electrical Equipment

Electrical Equipment
For distribution equipment & machinery.

 

 

BK Series Power Range

Available ratings from 500VA to 100kVA. Custom power ratings available for OEM & industrial project specifications.

CapacityAplikasi Umum
500VA – 1kVASmall control circuits
2kVA – 5kVAIndustrial machinery
5kVA – 10kVAControl cabinets & automation
10kVA – 25kVAIndustrial equipment
25kVA – 50kVALarge machinery
50kVA – 100kVAHigh-power control systems

Key Compliance & Features

  • CE & RoHS Compliant: Built to global industrial safety standard IEC 61558.
  • High-Efficiency Core: Cold-rolled silicon steel minimizes no-load loss.
  • Varnish Impregnated: Anti-humidity and low acoustic noise performance.

Technical Specifications

ParameterSpecification
Product TypeTrafo Pengatur Industri
SeriesBK Series
Rated Capacity500VA – 100kVA
FaseSingle Phase / Three Phase*
Input VoltageCustom Available
Output VoltageCustom Available
Frequency50Hz / 60Hz
Bahan LilitanTembaga / Aluminium
Insulation ClassClass B / F / H
Metode PendinginanNatural Air Cooling (AN)
InstallationIndoor / Cabinet Mount
Structure TypeOpen / Enclosed Type*
StandardsIEC / EN Standard Compliant
PenyesuaianOEM / ODM Support

Voltage Configurations

Primary (Input)

110V
220V
380V
400V
415V
440V
480V
500V
600V
660V

Secondary (Output)

12V
24V
36V
48V
110V
120V
220V
380V
+ Custom Voltage

💡 Flexible Engineering: VoltneX Power supports custom multi-tap designs, dual-voltage outputs, and special voltage steps based on project demands.

 

 

Customization Options

Power Rating
500VA – 100kVA & custom capacities.
Voltage Ratios
Tailored primary & secondary steps.
Bahan Lilitan
High-purity copper or aluminum.
Insulation System
Class B, F, or H rise ratings.
Dimensions & Mount
Adapted to enclosure layout.
Terminals & Wiring
Custom blocks or screw connectors.
OEM / ODM Support
Built strictly according to your engineering drawings and electrical specs.

How to Select a BK Transformer

01

Determine Primary (Input) Voltage
e.g., 220V, 380V, 415V, or 440V line supply.

02

Determine Secondary (Control) Voltage
e.g., 24V, 110V, or 220V control circuit load.

03

Calculate Total VA Capacity
Consider continuous load + total inrush current.

04

Select Winding & Material
Choose copper or aluminum based on budget.

05

Confirm Installation Requirements
Check dimensions, terminal orientation & cooling.
Need Help Selecting the Right Model?
Send us your voltage, VA rating & load profile for engineer assistance.

Operating Environment

Ambient Temp:
-5°C to +40°C
24h Avg Temp:
≤ +35°C
Altitude:
≤ 2,000m ASL

Suitable for industrial control cabinets & machinery.
Ensure adequate ventilation around high-capacity units.
Special anti-humidity / anti-vibration options available.

* Contact engineering team for high-altitude (>2000m) or high-humidity customization.

 

 

BK Series Industrial Control Transformer Dimension Drawing – Outline, Overall and Mounting Dimensions with Technical Specifications for Custom Industrial Power Applications – VoltNex Power
MODELMOUNTING HOLE PITCH (MM)EXTERNAL DIMENSIONS (MM)MOUNTING HOLE
(K X J)
ACB MAXD MAXE MAX
BK-25~5056±0.553±28074854.8 x 9
BK-10064±0.565±28684924.8 x 9
BK-15084±0.580±296971105.8 x 11
BK-20084±0.587±2961051105.8 x 11
BK-25084±0.590±2961101105.8 x 11
BK-30090±0.598±21201201257 x 13
BK-400~50090±0.5104±21351281257 x 13
BK-700110±0.597±21521251477 x 13
BK-1000111±0.5113±21701481657 x 13
Trafo Kontrol Industri Tipe Kering Seri BK dengan Lilitan Tembaga, Terminal Ganda, dan Struktur Pemasangan yang Dilengkapi Perlindungan untuk Aplikasi Kontrol Industri

 Industrial Control & Auxiliary Power Solutions

Produsen Trafo Kontrol Tipe Kering Tertutup Seri BK di Tiongkok untuk Panel Kontrol CNC dan Industri

Trafo Pengatur Tipe Kering Tertutup Seri BK

Trafo Pengatur Tipe Terbuka dan Tipe Kering Seri BK untuk Panel Kontrol Industri dan Mesin CNC

Trafo Pengatur Tipe Terbuka dan Tipe Kering Seri BK

Trafo Kontrol Industri Seri BK 500VA–100KVA dengan frekuensi 50Hz dan 60Hz, lilitan tembaga atau aluminium, Kelas F/H, dan tegangan sesuai pesanan

High Capacity Industrial Control Transformer

 

 

Direct Factory
ISO 9001 Certified
VoltneX Power Manufacturing
China-based Leader in Industrial Power Transformers

BK Control Transformer Manufacturer

VoltneX Power is a premier manufacturer and global supplier of high-performance industrial control transformers and power quality solutions. We deliver reliable BK Series transformers optimized for machinery builders, panel integrators, automation engineers, and OEM distributors worldwide.

Target Industries Served
• CNC Industrial Machinery & Automation
• Electrical Control Cabinets & Switchgears
• Power Distribution & HVAC Control Systems

Why Choose VoltneX
• 100% Copper Winding Option: High conductivity & minimal heat.
• Low Noise & Thermal Design: Vacuum pressure impregnated.
• Factory Direct Supply: Fast lead times & bulk wholesale prices.



Learn More About Our Factory →

Quality Assurance & Testing

100% factory inspection ensures absolute compliance with international safety standards before dispatch.

Routine Test Protocol
IEC 61558 Standard
  • ✓ Winding Resistance Test
  • ✓ Insulation Resistance Test
  • ✓ Dielectric Withstand Test (Hi-Pot)
  • ✓ No-Load Loss & Current Test
  • ✓ Load Loss & Impedance Test
  • ✓ Voltage Ratio & Vector Group Test
  • ✓ Temperature Rise Verification
  • ✓ Final Appearance & Dimension Inspection

Optional Type & Special Tests
• Short-Circuit Withstand Ability Test
• Acoustic Sound Level (dB) Measurement
• Salt Spray & Climate Resistance Testing

🛡️ Each transformer is strictly tested according to client technical datasheets prior to shipment.

OEM & ODM Custom Solutions

End-to-end engineering customization for global brand owners and project contractors.

01
Electrical Engineering
Custom voltage, capacity, multi-taps, frequency & duty cycles.
02
Mechanical Design
Tailored dimensions, mounting holes, terminal blocks & enclosures.
03
Branding & Private Label
Custom customer nameplate, logo, color, and technical schematics.
04
Export Packaging
Seaworthy wooden cases, customized inner cartons, and barcodes.
05
Flexible Production
Fast rapid prototyping samples and scalable volume manufacturing.

OEM / ODM Service Workflow
1. Inquiry
→
2. Drawing
→
3. Sample
→
4. Mass Batch

⚙️ Engineering Support: Send us your technical drawing or requirements for a free sample evaluation.

PERTANYAAN YANG SERING DIAJUKAN

A BK Series industrial control transformer is designed to provide stable and reliable control power for industrial machinery, machine tools, CNC machines, electrical control panels, automation equipment and auxiliary electrical circuits. It steps the available primary voltage down or up to the required control voltage for components such as contactors, relays, solenoid valves, PLC circuits, sensors, indicator lights and motor control circuits.

Compared with a general-purpose power transformer, a control transformer is designed specifically for control circuits where stable voltage and reliable performance during switching and inrush conditions are important. VoltNex Power supplies BK Series control transformers for industrial automation, machine-building and electrical equipment applications.

Search intent covered:
BK control transformer / industrial control transformer / control power transformer / machine control transformer / auxiliary power transformer

A BK control transformer is optimized for industrial control circuits rather than general power distribution. It is commonly used to provide a dedicated control voltage for contactors, relays, solenoids, PLCs, indicators and other control components.

Important selection factors include VA capacity, primary voltage, secondary voltage, inrush current, voltage regulation, frequency, insulation class and installation space. A standard power transformer may be suitable for some applications, but a properly selected control transformer is generally better suited to machinery control circuits with frequent switching and inductive loads.

Search intent covered:
control transformer vs transformer / control power transformer / industrial transformer / machine tool transformer

The BK Series page is positioned for 500VA to 100kVA industrial control transformer applications, with custom capacities available for OEM and project requirements. Typical application ranges include smaller control circuits, industrial machinery, control cabinets, automation equipment and higher-power industrial systems.

When selecting a rating, the transformer should be sized according to both the continuous VA load and the maximum inrush VA of connected devices such as contactors, solenoids, motors and other electromagnetic loads.

For a custom BK transformer, provide the required VA/kVA rating, primary voltage, secondary voltage, frequency and load profile so the engineering team can recommend the appropriate configuration.

Start by calculating the total steady-state VA load of all control components that may operate simultaneously. Then evaluate the maximum inrush VA produced when contactors, relays, solenoid valves or other inductive loads are energized.

A practical selection should consider:

  • Continuous control load
  • Maximum simultaneous load
  • Contactors and relay inrush
  • Solenoid inrush
  • PLC and electronic control loads
  • Motor starter circuits
  • Future load expansion

The selected control transformer should have sufficient capacity to prevent excessive voltage drop during starting or switching conditions. VoltNex Power can assist with sizing when you provide the load list and operating sequence.

VoltNex Power offers customized primary and secondary voltage configurations. Common primary voltages listed for the BK Series include 110V, 220V, 380V, 400V, 415V, 440V, 480V, 500V, 600V and 660V.

Common secondary control voltages include 12V, 24V, 36V, 48V, 110V, 120V, 220V and 380V, with special voltage combinations available for customized projects. Multi-tap and dual-voltage configurations can also be engineered according to the application.

For international OEM equipment, the primary and secondary voltages should be confirmed from the machine electrical schematic before ordering.

Yes. 24V, 110V and 220V are common control-voltage requirements, and the BK Series can be configured with different primary and secondary voltage combinations according to the project specification.

Typical applications include:

  • 24V control circuits
  • 24V relay and solenoid circuits
  • 110V machine control circuits
  • 110V lighting circuits
  • 220V control circuits
  • PLC and automation auxiliary power
  • Contactor and motor starter circuits

Custom voltage ratios and multi-tap configurations are also available for OEM machine builders and control-panel manufacturers.

Yes. BK Series industrial control transformers are designed for applications including CNC machines, machine tools, lathes, milling machines, grinding machines, machining equipment and industrial automation systems.

They can provide dedicated control power for electrical control cabinets, contactors, relays, PLC systems, machine lighting, sensors, solenoids and auxiliary circuits.

For CNC equipment, the transformer should be selected according to the machine’s actual input voltage, control voltage, VA requirement, inrush load, frequency and available installation space.

Our control transformers are manufactured with Class B (130°C), Class F (155°C), or Class H (180°C) high-temperature insulation materials using Vacuum Pressure Impregnation (VPI) process to ensure moisture resistance, superior dielectric strength, low noise, and strict compliance with IEC 61558, EN 61558, and CE safety standards.

Yes. BK Series control transformers can be supplied with copper or aluminum windings depending on electrical requirements, cost targets and project specifications.

Copper winding is commonly selected when customers prioritize high conductivity, compact design and lower winding losses. Aluminum winding can provide a more cost-oriented solution for suitable industrial applications.

For OEM projects, VoltNex Power can specify the winding material according to the required current, temperature rise, efficiency, dimensions and budget.

The BK Series can be configured with Class B, Class F or Class H insulation systems, depending on the required thermal performance and application conditions. The page currently lists Class B/F/H options.

For industrial machinery and automation applications, insulation selection should consider ambient temperature, load profile, enclosure ventilation, duty cycle and required temperature rise.

For special environments such as high humidity, high altitude or high-vibration applications, customized construction can be discussed with the engineering team.

Yes. The BK Series is offered for 50Hz and 60Hz industrial power systems, making it suitable for machinery and OEM equipment intended for different international markets.

This is particularly useful for manufacturers exporting CNC machines, machine tools, automation equipment and electrical control panels to markets such as the United States, Canada, Europe, Australia, Latin America and the Middle East.

However, the exact voltage and frequency combination should always be confirmed against the transformer nameplate and technical specification before production.

Both transformer types can provide electrical separation between primary and secondary circuits, but their design priorities are different.

A control transformer is primarily intended to supply reliable power to control circuits containing loads such as contactors, relays, solenoids and other switching devices. Its design takes control-circuit inrush and voltage stability into consideration.

Sebuah trafo isolasi is more commonly selected when the main objective is electrical isolation between circuits, equipment protection or power-quality-related applications.

For a machine control cabinet, a control transformer is generally the more application-specific choice when the load consists mainly of control components.

Yes. VoltNex Power provides OEM and ODM customization for industrial control transformer projects.

Customization can include:

  • Primary/input voltage
  • Secondary/output voltage
  • VA/kVA capacity
  • 50Hz / 60Hz frequency
  • Copper or aluminum winding
  • Class B / F / H insulation
  • Multi-tap voltage
  • Dual-voltage output
  • Transformer dimensions
  • Mounting-hole positions
  • Terminal blocks
  • Wiring configuration
  • Enclosure integration
  • Nameplate and branding

The transformer can be manufactured according to the customer’s electrical schematic, technical drawing, equipment specification or control-panel layout.

For an accurate quotation, provide as much of the following information as possible:

1. Primary voltage: e.g. 380V, 400V, 415V, 440V or 480V
2. Secondary voltage: e.g. 24V, 110V, 120V or 220V
3. Rated capacity: VA or kVA
4. Frequency: 50 Hz atau 60 Hz
5. Phase: single-phase or three-phase, if applicable
6. Winding: copper or aluminum
7. Insulation: Class B, F or H
8. Application: CNC machine, machine tool, control cabinet, automation equipment, etc.
9. Installation: dimensions, mounting holes and terminal requirements
10. Quantity: sample, small batch, wholesale or OEM production

For custom projects, providing the electrical schematic or existing transformer nameplate can significantly speed up technical evaluation and quotation

Yes. VoltNex Power provides factory-direct BK Series industrial control transformer manufacturing and wholesale supply for OEM machine builders, distributors, electrical panel manufacturers, automation companies and industrial equipment integrators.

Standard and customized transformers can be supplied for projects in North America, Europe, Latin America, the Middle East, Asia-Pacific and other international industrial markets. OEM/ODM services can include custom electrical specifications, mechanical dimensions, nameplates, private labeling, packaging and volume production.

For bulk orders, customers can request a quotation based on model, VA/kVA capacity, voltage, quantity, customization requirements and destination market.